Advanced calculator

Multiple load calculator

Build a complete load schedule for a flat, house, shop or small factory. Add every appliance with quantity, running hours and duty factor, then get total connected load, diversified maximum demand, phase current, breaker size, monthly units and a slab-wise taka estimate.

Load schedule

Duty factor is the share of rated wattage a device actually draws on average — leave it at 100% for resistive loads like irons and geysers, and lower it for compressors.

  • 2.30 kW connected · 227.7 kWh/mo

  • 0.30 kW connected · 90.0 kWh/mo

  • 0.11 kW connected · 19.4 kWh/mo

  • 0.15 kW connected · 37.8 kWh/mo

  • 0.25 kW connected · 68.4 kWh/mo

  • 2.00 kW connected · 60.0 kWh/mo

  • 0.50 kW connected · 15.0 kWh/mo

  • 1.10 kW connected · 16.5 kWh/mo

  • 0.13 kW connected · 19.5 kWh/mo

  • 0.75 kW connected · 22.5 kWh/mo

  • 0.04 kW connected · 32.4 kWh/mo

Supply & tariff settings

Share of connected load running at the same moment.

Applies only to loads flagged as peak-hour (TOU meters).

Estimated monthly bill

৳ 7,789

609 units · average ৳ 12.78/unit

Energy charge
৳ 6,560.31
Peak-hour surcharge
৳ 857.78
VAT (5%)
৳ 370.90
Yearly cost
৳ 93,468

Load & wiring summary

Total connected load
7.63 kW
Maximum demand (65%)
4.96 kW
Apparent power
5.84 kVA
Line current
25.4 A
Suggested main MCB
32 A
Sanctioned load to apply for
7.7 kW
Backup generator size
7.5 kVA
Solar array to offset fully
5.1 kWp

Your load schedule is saved in this browser only — nothing is uploaded.

Cost contribution by appliance

Ranked by share of the monthly bill, so you can see which loads are worth attacking first.

Monthly units and cost for each appliance in the load schedule
ApplianceQty × WConnected kWHrs/dayUnits/moCost/moShare
AC 1.5 ton (inverter)peak2 × 1150W2.306227.7৳ 2,911
37%
Ceiling fan4 × 75W0.301090.0৳ 1,151
15%
Deep freezer 250L1 × 250W0.252468.4৳ 874
11%
Geyser 30L1 × 2000W2.00160.0৳ 767
10%
Refrigerator 250L1 × 150W0.152437.8৳ 483
6%
IPS standby loss1 × 45W0.042432.4৳ 414
5%
Water pump 1 HP1 × 750W0.75122.5৳ 288
4%
LED TV 55 inchpeak1 × 130W0.13519.5৳ 249
3%
LED bulb 9W12 × 9W0.11619.4৳ 249
3%
Clothes iron1 × 1100W1.100.516.5৳ 211
3%
Washing machine1 × 500W0.50115.0৳ 192
2%

Slab-wise energy charge

LT-A slab breakdown for the total monthly units
SlabUnitsRateAmount
0–75 units75.06.18৳ 463.50
76–200 units125.08.50৳ 1,062.50
201–300 units100.09.10৳ 910.00
301–400 units100.09.62৳ 962.00
401–600 units200.015.01৳ 3,002.00
601+ units9.217.35৳ 160.31

How the numbers are calculated

Connected load is simply quantity × rated watts for every device, added up. It is the figure the distribution utility uses on your connection application, and it is always higher than what you actually draw, because you never switch everything on at once.

Maximum demand applies a diversity factor to the connected load. A typical residential flat runs at 55–70% diversity, a shop at 70–85%, and a small workshop with motors at 80–90%. Utilities in Bangladesh bill demand charges to MT and HT consumers on this diversified demand, not the connected total.

Line current uses I = P ÷ (V × pf) for single phase and I = P ÷ (√3 × V × pf) for three phase. Inductive loads such as motors, compressors and older fans push the power factor down toward 0.75–0.85, which raises current for the same kilowatts — that is why the calculator lets you set it.

Breaker size is the next standard MCB rating above 125% of the calculated current, following the usual continuous-load allowance. Treat it as a sanity check, not a design document: final selection must account for cable size, ambient temperature, fault level and the actual layout of your distribution board.

Monthly units multiply average draw (rated watts × duty factor) by hours per day and days per month. Duty factor matters enormously for anything with a compressor: a fridge is plugged in 24 hours but its compressor runs roughly a third of the time, and an inverter AC settles at 40–60% of rated power once the room is cool.

Typical diversity factors

Suggested diversity factor ranges by premises type
PremisesDiversityWhy
Studio / one-room flat70–80%Few devices, so most of them run together.
2–3 bedroom family flat55–70%Bedrooms and kitchen peak at different times.
Duplex / large house45–60%Large connected load, low simultaneous use.
Retail shop70–85%Lighting and cooling run continuously in business hours.
Restaurant60–75%Kitchen equipment cycles through service periods.
Small workshop with motors80–90%Machines run together during a shift.
Apartment building (common)35–50%Statistical smoothing across many flats.